Skip to content

CI230X Hardware test report

Wi-Fi conduction self-test report

Transmission power and EVM test

Table 1 Test Environment

Hardware version CI-E05GT02S V4.0
Software version V051C
Matching parameters 3.3pF//1.5pF-1nH
Test equipment WT-208

Table 2 Test Table of Transmission Power and EVM at 25 ℃ Room Temperature

TX MODE RATE CMCC CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13
11b 1 35% 19.2/4.3% 19.1/4.4% 19.2/4.5% 19.2/4.6% 19.3/4.6% 19.1/4.6% 18.9/4.5% 18.7/4.4% 18.9/4.3% 19.1/4.3% 19.1/4.4% 18.9/4.6% 18.9/4.6%
11 35% 18.6/4.9% 18.6/4.7% 18.8/4.9% 18.8/5.1% 18.9/5.2% 18.8/5.4% 18.7/5.1% 18.4/4.7% 18.6/4.8% 18.5/4.6% 18.6/5.0% 18.4/4.9% 18.4/5.1%
11g 6 -5 17.1/-26.5 17.1/-26.8 17.2/-26.5 17.2/-26.2 17.3/-25.5 17.2/-25.4 17.0/-25.9 16.8/-26.5 17.0/-26.3 16.8/-26.7 16.9/-26.5 16.9/-26.4 17.1/-25.7
54 -25 14.4/-31.5 14.5/-31.4 14.6/-31.2 14.6/-31.2 14.8/-31.0 14.6/-30.5 14.5/-30.9 14.1/-31.6 14.4/-31.2 14.2/-31.8 14.3/-31.5 14.4/-31.2 14.5/-31.1
11n MCS0 -5 16.4/-28.1 16.5/-28.1 16.5/-27.6 16.5/-27.6 16.7/-27.0 16.5/-26.8 16.3/-27.1 16.1/-27.8 16.3/-27.5 16.2/-28.0 16.2/-27.9 16.2/-27.9 16.4/-27.0
MCS7 -27 13.8/-31.9 13.8/-31.6 13.9/-32.1 13.9/-31.9 14.1/-31.6 13.9/-31.3 13.8/-31.7 13.5/-31.9 13.7/-31.8 13.7/-32.1 13.7/-32.2 13.7/-32.1 13.9/-31.5

RX sensitivity test

Table 3 RX sensitivity test at room temperature 25 ℃

RX MODE RATE CMCC CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13
11b 1 -88 -93.5 -93.5 -93.5 -93.5 -93.5 -93.5 -93.5 -93.5 -93.5 -93.5 -93.0 -93.0 -93.0
11 -81 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.5 -86.0
11g 6 -85 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.5 -90.0
54 -68 -75.0 -75.0 -75.0 -75.0 -75.0 -74.5 -74.5 -74.5 -74.5 -74.5 -74.5 -74.5 -74.5
11n MCS0 -85 -90.5 -90.5 -90.5 -90.5 -90.5 -90.0 -90.0 -90.0 -90.0 -90.0 -90.0 -90.0 -89.5
MCS7 -67 -71.0 -71.0 -71.0 -71.0 -70.5 -70.5 -70.5 -70.5 -70.5 -70.5 -70.5 -70.5 -70.0